EXIDE CORP -- NICKEL CADMIUM BATTERY -- 6140-00-449-9839
===================== Product Identification ===================== Product ID:NICKEL CADMIUM BATTERY MSDS Date:06/01/1988 FSC:6140 NIIN:00-449-9839 === Responsible Party === Company Name:EXIDE CORP Address:645 PENN ST City:READING State:PA ZIP:19612-4205 Country:US Info Phone Num:215-378-0798 Emergency Phone Num:215-378-0798 CAGE:20038 === Contractor Identification === Company Name:EXIDE CORP Address:645 PENN STREET Box:14205 City:READING State:PA ZIP:19612-4205 Country:US Phone:610-378-0500/0798 CAGE:20038 ============= Composition/Information on Ingredients ============= Ingred Name:NICKEL HYDROXIDE (SARA III) CAS:12054-48-7 RTECS #:QR7040000 Other REC Limits:NONE RECOMMENDED OSHA PEL:1 MG NI/M3 ACGIH TLV:0.1 MG NI/M3; 9293 EPA Rpt Qty:10 LBS DOT Rpt Qty:10 LBS Ingred Name:CADMIUM (SARA III) CAS:7440-43-9 RTECS #:EU9800000 Other REC Limits:NONE RECOMMENDED OSHA PEL:SEE 1910.1027 ACGIH TLV:0.01 MG/M3 DUST;9394 EPA Rpt Qty:10 LBS DOT Rpt Qty:10 LBS ===================== Hazards Identification ===================== Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES Health Hazards Acute and Chronic:CADMIUM - CARCINOGENIC AS DUST OR IF INGESTED. NONE DURING NORMAL USE. Explanation of Carcinogenicity:CONTAINS C [7440-43-9] WHICH IS LISTED BY NTP AND IARC AND REGULATED BY OSHA AS A CARCINOGEN. Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER. Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER. ======================= First Aid Measures ======================= First Aid:REMOVE FROM EXPOSURE - FLUSH ELECTROLYTE FROM SKIN OR EYES WITH WATER. FLUSH EYES 15 MIN - SEE PHYSICIAN. ===================== Fire Fighting Measures ===================== Autoignition Temp:Autoignition Temp Text:UNKNON Lower Limits:4.1 Upper Limits:74.2 Extinguishing Media:CARBON DIOXIDE; FOAM; DRY CHEMICAL; HALOGEN. Fire Fighting Procedures:IF ON CHARGE, SHUT OFF POWER. Unusual Fire/Explosion Hazard:WILL GENERATE HYDROGEN ON OVERCHARGING. ================== Accidental Release Measures ================== Spill Release Procedures:STOP FLOW OF MATEIAL, CONTAIN/ABSORB SMALL SPILLS WITH DRY SAND, EARTH, VERMICULITE. DO NOT USE COMBUSTIBLE MATERIALS. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:DO NOT BREAK OE INCINERATE. KEEP AWAY FROM IGNITION SOURCES DURING CHARGING. Other Precautions:CONTACT YOUR LOCAL EPA OFFICE FOR PROPER DISPOSAL METHODS. DO NOT SHORT TERMINALS WITH TOOLS, ETC. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:NONE SPECIFIED BY MANUFACTURER. Ventilation:MECHANICAL VENTILATION: 3-4 AIR CHRAGES/HOUR. Protective Gloves:RUBBER OR PLASTIC GLOVES. Eye Protection:CHEMICAL GOGGLES. Other Protective Equipment:NONE Work Hygienic Practices:NONE Supplemental Safety and Health NONE ================== Physical/Chemical Properties ================== HCC:B1 ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES NONE SPECIFIED BY MANUFACTURER. Stability Condition to Avoid:PROLONGED OVERCHARGING. Hazardous Decomposition Products:DO NOT INCINERATE OR OVERHEAT BATTERY. ==================== Disposal Considerations ==================== Waste Disposal Methods:MUST MEET ALL FEDERAL, STATE AND LOCAL REGULATIONS. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.